Subaru Forester

1997-2005 of release

Repair and operation of the car



Subaru Forester
+ Subaru Forester cars
+ Maintenance instruction
+ Routine maintenance
+ Engine
- Cooling systems, heating
   Specifications
   Antifreeze - general information
   Check of serviceability of functioning and replacement of the thermostat
   Removal and installation of the fan of the cooling system
   Service, removal and installation of a radiator of the cooling system
   Removal and installation of a filling tank (model with a turbo-supercharging)
   Removal, check and installation of the water pump
   System of heating and ventilation of salon - the general information
   Removal and installation of a heater
   Removal and installation of the fan of a heater
   Check of serviceability of functioning and service of systems of heating and air conditioning
+ Power supply system and release
+ Engine electric equipment
+ Control systems of the engine
+ Gear shifting box
+ Coupling, transmission line
+ Brake system
+ Suspension bracket and steering
+ Body
+ Onboard electric equipment


Specifications

General parameters

Volume of cooling liquid, l
Engines 2.0 l
Models with RKPP 6.4
Models with AT 6.3
Engines of 2.5 l 6.2

Water pump

Type Centrifugal
The account and pressure head characteristic (at a temperature of cooling liquid of 80 °C)
At engine turns 760 in a minute
20 l/min 0.3 m of water column.
100 l/min 5 m of water column.
200 l/min 23 m of water column.
Diameter of a krylchatka, mm 76
Number of shovels 8
Diameter of a shaft, mm 60
Gap size between a krylchatka and the case, mm
Nominal rate 0.5 ÷ 0.7
Extreme admissible value 1.0
Extreme admissible size of an axial side play, mm 0.5

Thermostat

Type Voskozapolnenny
Temperature of the beginning of opening, °C 76 ÷ 80
Temperature of full opening 91
Size of a raising of the valve, mm 9.0
Diameter of the valve, mm 35

Fan

Power of the electric motor, W
Models without turbo-supercharging 120
Models with a turbo-supercharging 140
Diameter of a krylchatka, mm 340

Radiator

Pressure of opening of the steam-air valve, kPa
Superfluous 88 ± 10
Depression depth - 4.9 ÷ - 9.8

Broad tank

Volume, l 0.6

Deflection of driving belts, mm

In the middle of belt length under effort of 98 N (10 kgfs)
Generator/power steering
New belt 7.0 – 9.0
Old belt 9.0 – 11.0
KV compressor
New belt 7.5 – 8.5
Old belt 9.0 – 10.0
Pressure of the valve of a cover of a radiator, bar
Models with EJ20J engines 0.8-1.0
Models with EJ20J engines 0.8-1.0
Temperature of opening of the thermostat 76-80 °C
Temperature sensor resistance
cooler
350-400 Ohm, at 80 °C

Efforts of tightening of threaded connections, Nanometer

Are provided also in the text of the Head and on accompanying illustrations.

Crankshaft pulley 122-137