Subaru Forester + Subaru Forester cars + Maintenance instruction + Routine maintenance + Engine - Cooling systems, heating Specifications Antifreeze - general information Check of serviceability of functioning and replacement of the thermostat Removal and installation of the fan of the cooling system Service, removal and installation of a radiator of the cooling system Removal and installation of a filling tank (model with a turbo-supercharging) Removal, check and installation of the water pump System of heating and ventilation of salon - the general information Removal and installation of a heater Removal and installation of the fan of a heater Check of serviceability of functioning and service of systems of heating and air conditioning + Power supply system and release + Engine electric equipment + Control systems of the engine + Gear shifting box + Coupling, transmission line + Brake system + Suspension bracket and steering + Body + Onboard electric equipment
|
Specifications
General parameters
| Volume of cooling liquid, l |
| Engines |
2.0 l |
| Models with RKPP |
6.4 |
| Models with AT |
6.3 |
| Engines of 2.5 l |
6.2 |
Water pump
| Type |
Centrifugal |
| The account and pressure head characteristic (at a temperature of cooling liquid of 80 °C) |
| At engine turns |
760 in a minute |
| 20 l/min |
0.3 m of water column. |
| 100 l/min |
5 m of water column. |
| 200 l/min |
23 m of water column. |
| Diameter of a krylchatka, mm |
76 |
| Number of shovels |
8 |
| Diameter of a shaft, mm |
60 |
| Gap size between a krylchatka and the case, mm |
| Nominal rate |
0.5 ÷ 0.7 |
| Extreme admissible value |
1.0 |
| Extreme admissible size of an axial side play, mm |
0.5 |
Thermostat
| Type |
Voskozapolnenny |
| Temperature of the beginning of opening, °C |
76 ÷ 80 |
| Temperature of full opening |
91 |
| Size of a raising of the valve, mm |
9.0 |
| Diameter of the valve, mm |
35 |
Fan
| Power of the electric motor, W |
| Models without turbo-supercharging |
120 |
| Models with a turbo-supercharging |
140 |
| Diameter of a krylchatka, mm |
340 |
Radiator
| Pressure of opening of the steam-air valve, kPa |
| Superfluous |
88 ± 10 |
| Depression depth |
- 4.9 ÷ - 9.8 |
Broad tank
Deflection of driving belts, mm
| In the middle of belt length under effort of 98 N (10 kgfs) |
| Generator/power steering |
| New belt |
7.0 – 9.0 |
| Old belt |
9.0 – 11.0 |
| KV compressor |
| New belt |
7.5 – 8.5 |
| Old belt |
9.0 – 10.0 |
| Pressure of the valve of a cover of a radiator, bar |
| Models with EJ20J engines |
0.8-1.0 |
| Models with EJ20J engines |
0.8-1.0 |
| Temperature of opening of the thermostat |
76-80 °C |
Temperature sensor resistance cooler |
350-400 Ohm, at 80 °C |
Efforts of tightening of threaded connections, Nanometer
Are provided also in the text of the Head and on accompanying illustrations.
| Crankshaft pulley |
122-137 |
|
|